Fiber laser intracavity absorption spectroscopy of ammonia and hydrogen cyanide in low pressure hydrocarbon flames

A. Goldman, I. Rahinov, S. Cheskis, B. Löhden, S. Wexler, K. Sengstock, V. M. Baev

פרסום מחקרי: פרסום בכתב עתמאמרביקורת עמיתים

תקציר

Fiber laser intracavity spectroscopy (FLICAS) with Er-doped fiber laser has been applied for the first in situ detection of ammonia and hydrogen cyanide in a low pressure (30 Torr) stoichiometric methane/nitrogen/oxygen flame doped with 0.13-1.36% of NH3. High resolution spectra of NH3 and HCN have been recorded in the range of 1.5 μm (6440-6540 cm-1). The minimum detectable concentration of HCN and NH3 at a laser pulse duration of 8 μs and room temperature is 1 × 1013 molecule/cm3. The method can be used for in situ detection of many other molecules in the hostile combustion environment.

שפה מקוריתאנגלית
עמודים (מ-עד)147-151
מספר עמודים5
כתב עתChemical Physics Letters
כרך423
מספר גיליון1-3
מזהי עצם דיגיטלי (DOIs)
סטטוס פרסוםפורסם - 20 מאי 2006
פורסם באופן חיצוניכן

הערה ביבליוגרפית

Funding Information:
This research was supported by the Israel Science Foundation (Grant No. 750/05) and by the James Franck, German-Israeli Binational Program in Laser Matter Interaction. The authors thank Bera Pálsdóttir and Christian Larsen from OFS Fitel, Denmark, for providing us with the Er-doped fiber.

טביעת אצבע

להלן מוצגים תחומי המחקר של הפרסום 'Fiber laser intracavity absorption spectroscopy of ammonia and hydrogen cyanide in low pressure hydrocarbon flames'. יחד הם יוצרים טביעת אצבע ייחודית.

פורמט ציטוט ביבליוגרפי